Start With the Obvious: Is It Turned On?
Make sure both radiator valves are open. Somebody may have turned the radiator off and forgotten about it. If opening the valve makes it heat straight away, there was nothing else wrong.
Thermostatic radiator valves are also notorious for sticking after summer. A normal TRV does not communicate with the boiler: it reacts to the temperature of the air around it. The wax inside expands as the room warms and pushes a small pin down to close the valve.
Check the TRV Pin
During warm weather the wax remains expanded and the pin can sit closed for weeks. When the heating comes back on, that little pin sometimes stays stuck down.
You are removing the plastic head, not undoing the metal valve body from the pipework. Stop if the pin will not free or any water appears.
Upstairs or Downstairs Makes a Difference
Highest Radiator Is Cold
Air rises, so a cold radiator on the top floor or in a loft conversion may contain air. Check the system pressure as well. A boiler downstairs may still run at 0.6 bar while only about 0.1 bar remains at the top of a tall house—not enough to fill that radiator properly.
Ground-Floor Radiator Is Cold
In a typical house, a completely cold lounge radiator downstairs is unlikely to be full of air while the upstairs radiators work normally. Start thinking about valves, flow, balancing or sludge.
Feel Both Radiator Pipes
Once the valves are open and the TRV pin moves, feel the two pipes connected to the radiator. Their temperatures tell you what is happening.
Both Pipes Cold
No flow is reaching the radiator.
One Hot, One Cold
Heat is arriving, but the flow through the radiator is poor or restricted.
Both Pipes Warm, Radiator Cold
The radiator itself is likely to be badly restricted with sludge.
Force the Water Through the Cold Radiator
Water always takes the easiest route. Leave the heating running, keep the problem radiator open and temporarily turn every other radiator off. This removes the easy routes and forces the pump towards the cold one.
Remember to reopen the other radiators after the test.
What Does Balancing Actually Do?
A modern boiler responds to the temperature of the water returning to it. If hot water takes the easy route through radiators close to the boiler or pump and comes back hot, the boiler can modulate down even though a distant radiator is still freezing.
Balancing restricts those easy routes and encourages water to travel where it is needed. I start nearest the boiler or pump with the lockshield only slightly open, then work away from the heat source and allow progressively more flow. The furthest or problem radiator is left open the most.
A complete balancing job means adjusting several lockshield valves in small increments and retesting the whole system. If the forced-flow test proves the radiator works but you are not confident balancing it, that is the point to call.
When the System May Need Cleaning
Cold areas across the bottoms of radiators, poor flow through several radiators, dirty system water or a boiler repeatedly firing and stopping without properly warming the house can point towards contamination and restricted circulation.
Bleeding will not remove sludge. At that stage it is worth considering proper system cleaning or power flushing.
Read about power flushing and system cleaning →You’ve Done the Basics—Know When to Stop
You may have saved yourself paying for a pointless call-out by checking the valve position, TRV pin, pressure, air and forced flow. But stop and call a heating engineer if:
- The TRV pin will not free
- Water appears around a valve
- The radiator stays cold with every other radiator turned off
- The boiler pressure keeps dropping after bleeding
- Several radiators have cold bottoms or poor flow
- The boiler repeatedly fires and stops without heating the house